SUN Liangliang, YUAN Yanping, HU Wenju, et al. Sensitivity analysis of configuration parameters of water-type PV/T module[J]. CIESC Journal, 2014, (z2): 235-239.
SUN Liangliang, YUAN Yanping, HU Wenju, et al. Sensitivity analysis of configuration parameters of water-type PV/T module[J]. CIESC Journal, 2014, (z2): 235-239.DOI: 10.3969/j.issn.0438-1157.2014.z2.035.
The sensitivity analysis of main configuration parameters of water-type PV/T module including thickness of cover glass
thickness of air gap
thickness of thermal absorber
diameter of water tube
spacing of water tube and thickness of thermal insulation material has been conducted using normalized sensitivity coefficient method. The impact of solar radiation
outdoor air temperature and flow rate on sensitivity coefficients of these configuration parameters are also investigated. It indicates that thickness of cover glass
diameter of water tube and spacing of water tube are significant influence parameters in term of electrical power generation and thermal heat for hot water. Compared with solar radiation and flow rate
effect of outdoor air temperature on sensitivity coefficients is not obvious.