FU Kunming, ZHANG Jie, CAO Xiangsheng, et al. Start-up of CANON reactor with modified polyethylene carrier and its performance[J]. CIESC Journal, 2014, (11): 4406-4412.
FU Kunming, ZHANG Jie, CAO Xiangsheng, et al. Start-up of CANON reactor with modified polyethylene carrier and its performance[J]. CIESC Journal, 2014, (11): 4406-4412.DOI: 10.3969/j.issn.0438-1157.2014.11.027.
A CANON reactor with modified polyethylene carrier was started up by seeding sludge from another mature CANON reactor and using artificial inorganic ammonia-rich waste water as influent. To accelerate ANAMMOX bacteria cultivation
the start-up was under anaerobic conditions first to avoid dissolved oxygen inhibition on ANAMMOX bacteria
and then under aerobic conditions. The reactor was first under anaerobic conditions to start ANAMMOX process at room temperature [(20±5)℃] in first 300 days
however
total nitrogen removal load was only 0.12 kg·(m3·d)-1
which meant failure of ANAMMOX. When temperature was increased to 30℃
30 days later
total nitrogen removal load was up to 0.23 kg·(m3·d)-1. Then anaerobic conditions was changed to aerobic conditions
and total nitrogen removal load was up to 1.01 kg·(m3·d)-1
while nitrogen removal efficiency was 77.61%
and average variation ratio of nitrate and nitrogen (δNO3--N/δTN) was 0.122
close to theoretical value 0.127
showing both good stability of nitritation and good nitrogen removal. Adopting the way of anaerobic stage first and then aerobic stage could not accelerate ANAMMOX bacteria cultivation as expected
and modified polyethylene carrier was not a suitable carrier to start ANAMMOX process under anaerobic conditions. However
once the reactor was successfully started up
aeration could be saved
though it might perform unstably. Modified polyethylene carrier was suggested to combine with UASB reactor to keep bacteria.