LIU Chaopeng, WU Jianghong, HUANG Yihe, et al. Performance evaluation and energy efficiency analysis for magnetic refrigeration near room temperature[J]. CIESC Journal, 2014, (9): 3654-3660.
LIU Chaopeng, WU Jianghong, HUANG Yihe, et al. Performance evaluation and energy efficiency analysis for magnetic refrigeration near room temperature[J]. CIESC Journal, 2014, (9): 3654-3660.DOI: 10.3969/j.issn.0438-1157.2014.09.047.
was proposed to evaluate the performance of magnetic refrigerator rationally and compensate for the limitation in evaluating magnetic refrigerator system with available two indexes
temperature span and cooling capacity. To testify the feasibility of exergetic efficiency evaluation indexes
the experimental data by University of Victoria in the form of temperature span-heat source temperature curve and experimental data by Technical University of Denmark in the form of temperature span-cooling capacity curve were converted to the temperature span-exergetic cooling capacities. Furthermore an experimental platform was established based on Sichuan University magnetic refrigerator prototype. With the heat source temperature controlled at 25
27 and 30℃
performance parameters of refrigerator such as cooling capacity
temperature span
cooling exergy and exergetic efficiency were obtained. Experimental results indicated that the cooling capacity of the magnetic refrigerator prototype could reach 240 W and its maximum cooling exergy was 3.26 W at heat source temperature 30℃ and 6 r·min-1. With the efficiencies of motor loss