XU Ying, CHEN Yang, BA Xili, et al. Over-reading prediction model of wet gas measurement using Z-shaped gas ultrasonic flow meter[J]. CIESC Journal, 2013, (11): 4031-4038.
XU Ying, CHEN Yang, BA Xili, et al. Over-reading prediction model of wet gas measurement using Z-shaped gas ultrasonic flow meter[J]. CIESC Journal, 2013, (11): 4031-4038.DOI: 10.3969/j.issn.0438-1157.2013.11.020.
In order to investigate the over-reading prediction model of wet gas measurement using gas ultrasonic flow meter
a Z-shaped gas ultrasonic flow meter prototype was selected to analyze its measuring principle and mechanism of over-reading when metering wet gas flow.The laboratory tests were conducted in TJU adjustable medium-pressure wet gas test loop.The over-reading of Z-shaped gas ultrasonic flow meter was mainly related to the void fraction of the pipe under a uniform film assumption with annular flow.Meanwhile
the correlation between void fraction and over-reading was deduced.Five typical void fraction correlations of gas/liquid two-phase flow in horizontal circular pipe were selected to calculate the predicted value of over-reading.The most appropriate void fraction correlation for predicting over-reading of Z-shaped type gas ultrasonic flow meter was the Armand-Massina correlation.The over-reading prediction model based on this void fraction correlation had prediction relative errors ranging from-7.77% to 4.90%
with a standard uncertainty of 0.98% at 95% confidence interval.