HUANG Cong, WANG Hualin, CHEN Cong, et al. Performance comparison between U-U and Z-Z type parallel arrangement of mini-hydrocyclone group[J]. CIESC Journal, 2013, (2): 624-632.
HUANG Cong, WANG Hualin, CHEN Cong, et al. Performance comparison between U-U and Z-Z type parallel arrangement of mini-hydrocyclone group[J]. CIESC Journal, 2013, (2): 624-632.DOI: 10.3969/j.issn.0438-1157.2013.02.029.
It is common to use multiple mini-hydrocyclones in parallel arrangement for large-scale industrial applications.For two typical parallel arrangements in mini-hydrocyclone group
U-U type and Z-Z type
the characteristics of pressure drop and flow distribution were investigated and compared by using theoretical model and experiments.It is found theoretically that the value of Q3+R2 has great influence on the performance of both parallel arrangements
where Q and R represent the momentum and the friction effects.The performance of U-U arrangement is better if Q3+R2<0
while that of Z-Z arrangement is better if Q3+R2>0.The experimental results show that the Z-Z arrangement presents better pressure drop distribution than the U-U type for 0.05≤P<0.10 MPa
but the flow distribution of both parallel arrangements is non-uniform under the condition.At P=0.10 MPa
uniform pressure drop and flow distribution are found for both arrangements.For 0.10<P≤0.15 MPa
the flow distribution of U-U arrangement is more uniform than Z-Z type.The pressure drop distribution of both arrangements has the same trend and is good.