Aiming at the household air source heat pump for “coal to electricity”
a capillary as a throttle element is proposed to replace the thermal expansion valve or the electronic expansion valve
and an experimental device for heat pump system was set up. The influence of different capillary length on the compressor suction pressure
exhaust temperature and heat capacity of the unit under variable frequency regulation of compressor were experimentally studied. The experimental results show that
after replacing the thermal expansion valve or the electronic expansion valve
the system can run stably for a long time. The system has the best thermal performance when the capillary length is 500 mm and the compressor frequency is 35 Hz
and the heating capacity and heating COP are the largest
but the suction pressure and the exhaust temperature are moderate.