ZENG Yangping, CHEN Xi, JIANG Zhenhua, et al. Influence of active phase compressor on performance of pulse tube cryocoolers[J]. CIESC Journal, 2018, (4): 1638-1645.
ZENG Yangping, CHEN Xi, JIANG Zhenhua, et al. Influence of active phase compressor on performance of pulse tube cryocoolers[J]. CIESC Journal, 2018, (4): 1638-1645.DOI: 10.11949/j.issn.0438-1157.20170628.
The experimental performance of a pulse tube cryocooler (PTC) with an active phase compressor (APC) is presented. In order to investigate the phase shifting ability of APC
phase locked loop (PLL) was adopted to control APC's voltage amplitude and phase between APC and main compressor (MC). When the voltage phase (APC lags MC) are 210° and 240°
performances of the cryocooler are tested under the displacement phase angle of 90°-130°. The results show that PTC with APC performs differently when the cryocooler working at different voltage phases
though displacement phase angle is the same. Comparing with PTC with inertance tube (IT)
performance of PTC with APC is better. Specifically
if cooling power is 30W
input power of PTC with APC decreased 8.1%. At last
from the perspective of phase shifting and matching with compressor
the reason why PTC performs differently under different phase-shifting method is demonstrated
which indicates APC could replace IT to shift PTC's phase.