LI Yuxing, CHANG Xueyu, ZHU Jianlu, et al. Experimental analysis of natural gas liquefaction process with double mixed refrigerant[J]. CIESC Journal, 2017, (5): 2122-2131.
LI Yuxing, CHANG Xueyu, ZHU Jianlu, et al. Experimental analysis of natural gas liquefaction process with double mixed refrigerant[J]. CIESC Journal, 2017, (5): 2122-2131.DOI: 10.11949/j.issn.0438-1157.20161313.
LNG-FPSO has great significance for the development of offshore gas field. The DMR liquefaction process has high efficiency and large capacity
which has obvious advantages under the conditions of stable sea and large amount of gas. The research verified the accuracy of the double mixed refrigerant flow
using the floating DMR experimental device which belongs to CNOOC Gas Electric R & D Center. The article analyzed the sensitivity of the NG's temperature
flow rate
and compressor frequency
and gave an assessment to the maritime adaptation. The experiment showed that the DMR process would be suitable in stable sea condition and mid to large-scale LNG production
and was not sensitive to the changes of gas temperature and pressure
it can effectively reduce the system energy consumption under low load by using inverter compress.