A test bench was built to study the dynamic characteristics of a binary ice vacuum system. The tests started with the same initial temperature and preset pressure but different jet flow. By collecting the indoor parameters of the flash such as temperature
pressure and so on
the influence of flow and solid adsorption module on the dynamic binary ice preparation process was analyzed qualitatively. The results showed that of the higher the flow rate
the lower the equilibrium pressure
while indoor balance temperature of the flash basically remained unchanged
maintaining at about 0℃. Through measuring the content of ice
it was found that the high flow rate was not favorable to the formation of ice crystals
while the low injection rate was relatively good for it. With adsorption it was more likely to achieve the dynamic balance and to maintain the balance at low pressure.