CAO Le, LIU Jinping, XU Xiongwen, et al. Overall heat transfer coefficient of plate-fin heat exchanger during a mixed refrigerant cryogenic process in low quality[J]. CIESC Journal, 2016, (4): 1277-1286.
CAO Le, LIU Jinping, XU Xiongwen, et al. Overall heat transfer coefficient of plate-fin heat exchanger during a mixed refrigerant cryogenic process in low quality[J]. CIESC Journal, 2016, (4): 1277-1286.DOI: 10.11949/j.issn.0438-1157.20151177.
Plate-fin heat exchangers (PFHEs) are mostly employed in medium- and small-sized LNG plants. However
works about the heat transfer characteristic optimization of mixed refrigerant in PFHE under low quality have been barely carried out nowadays. Thus
a Linde-Hampson cycle using single stage compressors and recuperative heat exchanger was established and mixed refrigerant (N2-CH4-C2H4-C3H8-iC4H10) was used to obtain the refrigeration temperature of -160℃. Meanwhile
the overall heat transfer coefficient and the correlational influence factor were mainly analysed. The experimental results showed that the overall heat transfer coefficient of the PFHE was about 2.6—22.7 W·m-2·K-1 while the refrigeration temperature and the circulated composition had week influence on the overall heat transfer coefficient. Meanwhile
the existing correlations cannot accurately predict the heat transfer coefficient of the mixed refrigerant under low quality and low flow velocity. However
the correlation of Cavallini and modified Granryd can used to predict the HTC of mixed refrigerant under low quality and low flow velocity after modification in this work. Additionally
some suggestion have been proposed in the design and optimization of PFHEs considering the refrigerate flowrate and pressure drop.