CHANG Cheng, JI Zhongli, HUANG Jinbin, et al. Analysis of re-entrainment in process of gas-liquid filtration[J]. CIESC Journal, 2015, (4): 1344-1352.DOI: 10.11949/j.issn.0438-1157.20141731.
safe operation of compressor units is seriously affected by droplets entrained in natural gas. The characteristics of re-entrainment in gas-liquid filtration process of filter cartridges were investigated using liquid aerosol of di-ethyl-hexyl-sebacate (DEHS). The effects of filter material wettability and filtration velocity on re-entrainment were also evaluated experimentally. Re-entrainment could be observed in the process of filtration as filter cartridges only composed of coalescing layers. More droplets were entrained into the downstream due to re-entrainment and some large particles could be detected at the downstream. Cumulative efficiency decreased at the large particle size at steady state. Re-entrainment was affected by filter material wettability. Compared with non-wettable filter material
re-entrainment was more obvious on the surface of wettable filter material. To improve filtration efficiency
non-wettable filter material were more suitable for producing industrial filter cartridges at the same filtration velocity. As filtration speed increased from 0.1 m·s-1 to 0.3 m·s-1
higher filtration velocity led to less re-entrainment
and filtration performance of wettable filter cartridges were improved more significantly than that of non-wettable filter cartridges. Re-entrainment could be eliminated by adding drainage layer to filter cartridges.