By using the trapping microphotographical technique
the drop size distribution of the aviation kerosene and carbon tetrachloride mixture-deionized water system has been measured in three stirred tanks of 184
287 and 494 mm in diameter with impellers of the frame-plate type. Based upon the mechanism of dispersion
model relations have been proposed and the model parameters determined by experiments. So a relation of the variation of drop size distribution with equipment geometry
operation parameters and phase ratio has been given. According to this relation
some relevant scale-up criteria have been obtained.