The two-probe sensor and rapid changing color high speed photograghy techniques were used in the determination of the initial projection velocities of droplets on sieve trays operating in spray regime. The experimental results confirm that the photographic method can be complemented by the dual probe sensor method in the measurement of the initial projection velocities. A new correktion was obtained to predict the relationship between the initial projection velocities