The paper puts forward a method of combining round cylinder pressure drop - turbine meter for measuring gas - lipuid flow in a duct. The characteristics of this method were investigated in the experiments. By means of computer control
the performance of the experiments with volume fractions β=0. 0
0. 3
0. 5
0. 8 and 1. 0 was measured. Based on the observation and analysis
an equation for the round cylinder pressure drop - turbine meter measurement was developed. A theoretical discussion of the measurement method was presented.