Experiments were conducted to study the heat transfer characteristics of water flowing through triangular silicon microchannels with a hydraulic diameter of 155.3 μm.The ratio of axial heat conduction to the whole heating and the axial heat conduction number were used to evaluate the effect of axial heat conduction on heat transfer in microchannelsThe thermal entry lengths for all cases were calculated based on experimental resultsThe measurements by IR camera showed that the local wall temperature did not change linearly along the channel
which was mainly caused by the axial heat conduction in the wallAnd the local Nusselt number distributions along the flow direction were calculated based on experimental resultsThe ratio of the axial heat conduction to the whole heating varied from 0.106 to 0.275
indicating that the axial heat conduction might play an important role in heat transfer in microchannels
especially when Reynolds number was lowThe axial heat conduction number was modified in the present studyThe experimental study revealed that the axial heat conduction number decreased with increasing Reynolds number when keeping heat input and inlet water temperature nearly constant.