Optimal control strategy for HVAC system of airport terminal based on optimal schedule time of AHU for pre-cooling
An optimal control strategy for HVAC system of an airport terminal based on the optimal schedule time of AHU for pre-cooling is presented.According to this optimal control strategy
a BPNN model is established to predict the optimal schedule time of AHU for pre-cooling
which is used as references to control AHU operation.Comparing with the original control strategy
this optimal control strategy can maintain indoor thermal comfort and save the power consumption of HVAC system.And the sensitivity analysis of BPNN model shows that the indoor dry-bulb temperature has a great impact on prediction accuracy of this BPNN model.