梁天水, 王宗莹, 高坤, 李润婉, 王铮, 钟委, 赵军. 基于cup burner的含铁基添加剂超细水雾灭火有效性分析[J]. 化工学报, 2019, 70(3): 1236-1242
LIANG Tianshui, WANG Zongying, GAO Kun, LI Runwan, WANG Zheng, ZHONG Wei, ZHAO Jun. Analysis of fire suppression effectiveness of ultra-fine water mist containing iron compounds additives in cup burner[J]. CIESC Journal, 2019, 70(3): 1236-1242
梁天水, 王宗莹, 高坤, 李润婉, 王铮, 钟委, 赵军. 基于cup burner的含铁基添加剂超细水雾灭火有效性分析[J]. 化工学报, 2019, 70(3): 1236-1242 DOI: 10.11949/j.issn.0438-1157.20180654.
LIANG Tianshui, WANG Zongying, GAO Kun, LI Runwan, WANG Zheng, ZHONG Wei, ZHAO Jun. Analysis of fire suppression effectiveness of ultra-fine water mist containing iron compounds additives in cup burner[J]. CIESC Journal, 2019, 70(3): 1236-1242 DOI: 10.11949/j.issn.0438-1157.20180654.
针对典型的液体燃料(乙醇和正庚烷)油池火焰,在自行搭建的实验台上对含铁基添加剂的超细水雾的临界灭火浓度进行测量,定量评价其灭火性能。为深入分析铁基添加剂的灭火机理,基于密度泛函理论,对铁氧化物与H自由基反应产物的结构进行优化计算。研究表明:二茂铁与硫酸亚铁添加剂均能使超细水雾的临界灭火浓度呈现不同程度的降低,并且存在最佳浓度。二茂铁与硫酸亚铁的质量分数分别为0.01%和1%时,灭火效果最好;含铁基添加剂细水雾灭乙醇火的效果好于正庚烷火。铁氧化物与H自由基反应生成的Fe(OH)
2
是一种活性催化物质,能够通过链式反应消去H自由基。
To evaluate
the fire suppression effectiveness of ultra-fine water mist containing iron compounds additives qualitatively and quantitively
a small-scale experiment platform was set up to explore the minimum extinguishing concentration of the water mist under different fuels. Ethanol and
n
-heptane were separately used as fuels. Air flow was kept as 60 L/min during experiments. The water mist content in the air was gradually increased by adjusting the power of atomizer. The critical fire suppression concentration was obtained until fire was extinguished. Furthermore
to understand the fire suppression mechanisms deeply
structures formed by iron oxides and H radicals were relaxed based on the density functional theory. The results show that ferrocene and ferrous sulfate can obviously reduce the minimum extinguishing concentration of ultra-fine water mist. The decreasing degree of minimum extinguishing concentration is not linear with the content of additives. There are optimal concentrations of iron compounds additives match to fire suppression effectiveness of the water mist. The optimal concentrations of ferrocene and ferrous sulfate are 0.01% and 1% respectively. The fire suppression effectiveness is affected by the type of fuels. Its order is as following in this experiment: ethanol
>
n
-heptane. Fe(OH)
2
formed by the reaction of iron oxide with H radical is an active catalytic substance capable of eliminating H radicals by chain reaction.
Adiga K C , Hatcher Jr R F , Sheinson R S , et al . A computational and experimental study of ultra fine water mist as a total flooding agent [J ] . Fire Safety Journal , 2007 , 42 ( 2 ): 150 - 160 .
裴蓓 , 余明高 , 陈立伟 , 等 . CO 2 -双流体细水雾抑制管道甲烷爆炸实验 [J ] . 化工学报 , 2016 , 67 ( 7 ): 3101 - 3108 .
Pei B , Yu M G , Chen L W , et al . Suppression effect of CO 2 -twin fluid water mist on methane/air explosion invented duct [J ] . CIESC Journal , 2016 , 67 ( 7 ): 3101 - 3108 .
纪虹 , 杨克 , 黄维秋 , 等 . 超细水雾协同甲烷氧化菌降解与抑制甲烷爆炸的实验研究 [J ] . 化工学报 , 2017 , 68 ( 11 ): 4461 - 4468 .
Ji H , Yang K , Huang W Q , et al . Methane degradation and explosion inhibition by using ultrafine water mist containing methane oxidative bacteria-inorganic salt [J ] . CIESC Journal , 2017 , 68 ( 11 ): 4461 - 4468 .
Adiga K C . Ultrafine water mist fire suppression technology [J ] . Fire Engineering , 2005 , 158 ( 1 ): 197 - 200 .
Ramagopal A , Richard C . Ultra-fine water mist extinction dynamics of a co-flow diffusion flame [J ] . Combustion Science & Technology , 2008 , 180 ( 9 ): 1659 - 1692 .
Iii G G B , Beyler C L , Hansen R . The capabilities and limitations of total flooding, water mist fire suppression systems in machinery space applications [J ] . Fire Technology , 2000 , 36 ( 1 ): 8 - 23 .
余明高 , 吴丽洁 , 万少杰 , 等 . 含NaCl荷电细水雾对甲烷爆炸火焰传播的抑制特性 [J ] . 化工学报 , 2017 , 68 ( 11 ): 4445 - 4452 .
Yu M G , Wu L J , Wan S J , et al . Inhibition characteristics on methane explosion flame propagation affected by charged water mist containing sodium chloride additive [J ] . CIESC Journal , 2017 , 68 ( 11 ): 4445 - 4452 .
Korobeinichev O P , Shmakov A G , Shvartsberg V M , et al . Fire suppression by low-volatile chemically active fire suppressants using aerosol technology [J ] . Fire Safety Journal , 2012 , 51 ( 4 ): 102 - 109 .
梁天水 , 李润婉 , 张单单 , 等 . 含添加剂细水雾熄灭醇类火焰的有效性实验研究 [J ] . 郑州大学学报(工学版) , 2018 , 39 ( 3 ): 5 - 9 .
Liang T S , Li R W , Zhang D D , et al . Experimental study on the effectiveness of water mist containing additives to extinguish alcohol flame [J ] . Zhengzhou University Journal (Engineering Science) , 2018 , 39 ( 3 ): 5 - 9 .
廖光煊 , 丛北华 , 况凯骞 . 铁基添加剂增强细水雾灭火性能的实验研究 [J ] . 工程热物理学报 , 2005 , 26 (S 1 ): 273 - 276 .
Liao G X , Cong B H , Kuang K Q . Experimental study on the fire suppression effectiveness of water mist with iron compounds additives [J ] . Journal of Engineering Thermophysics , 2005 , 26 (S 1 ): 273 - 276 .
余明高 , 郝强 , 段玉龙 , 等 . 二茂铁灭火实验平台研制与灭火有效性研究 [J ] . 火灾科学 , 2007 , 16 ( 2 ): 86 - 90 .
Yu M G , Hao Q , Duan Y L , et al . Study on experimental platform and fire suppression effectiveness of ferrocene [J ] . Fire Safety Science , 2017 , 16 ( 2 ): 86 - 90 .
Reinelt D , Linteris G T . Experimental study of the inhibition of premixed and diffusion flames by iron pentacarbonyl [J ] . Symposium on Combustion , 1996 , 26 ( 1 ): 1421 - 1428 .
Guo H , Liu H . Ferrocene-based fire extinguishing composition: US8778213 [P ] . 2014 .
Koshiba Y , Iida K , Ohtani H . Fire extinguishing properties of novel ferrocene/surfynol 465 dispersions [J ] . Fire Safety Journal , 2015 , 72 : 1 - 6 .
Koshiba Y , Ohtani H . Extinguishing pool fires with aqueous ferrocene dispersions containing gemini surfactants [J ] . Journal of Loss Prevention in the Process Industries , 2016 , 40 : 10 - 16 .
Koshiba Y , Okazaki S , Ohtani H . Experimental investigation of the fire extinguishing capability of ferrocene-containing water mist [J ] . Fire Safety Journal , 2016 , 83 : 90 - 98 .
李志峰 , 左秋玲 . 二茂铁对正庚烷池火抑制特性的实验研究 [J ] . 消防科学与技术 , 2010 , 29 ( 9 ): 752 - 754 .
Li Z F , Zuo Q L . Study on suppression characteristic of heptane fire and ferrocene [J ] . Fire Science and Technology , 2010 , 29 ( 9 ): 752 - 754 .
Vnapee M , Shirodkar P P . A study of flame inhibition by metal compounds [J ] . Symposium on Combustion , 1979 , 17 ( 1 ): 787 - 795 .
Rumminger M D , Reinelt D , Babushok V , et al . Numerical study of the inhibition of premixed and diffusion flames by iron pentacarbonyl [J ] . Combustion & Flame , 1999 , 128 ( 1 / 2 ): 145 - 164 .
Rumminger M D , Linteris G T . Numerical modeling of counter flow diffusion flames inhibited by iron pentacarbonyl [J ] . Fire Safety Science , 2000 , 6 : 289 - 300 .
Linteris G T . Final Report: Effective Non-Toxic Metallic Fire Suppressants [R ] . USA : NIST , 2002 .
Underwriters Laboratories Inc . Standard for halocarbon clean agent extinguishing system units: UL-2166 [S ] . USA : Northbrook , 1999 .
National Fire Protection Association . Standard for clean agent fire extinguishing systems: NFPA 2001 [S ] . USA : Quincy , 2004 .
Liang T S , Li R W , Li J , et al . Extinguishment of hydrocarbon pool fires by ultrafine water mist with ammonium/amidogen compound in an improved cup burner [J ] . Fire & Materials , 2018 , ( 3 ): 1 - 8 .
Zhang T W , Han Z Y , Du Z M , et al . Application of thermal mechanism to evaluate the effectiveness of the extinguishment of CH 4 /air cup-burner flame by water mist with additives [J ] . International Journal of Hydrogen Energy , 2016 , 41 ( 33 ): 15078-15088 .
Kresse G , Furthmuller J . Efficiency of ab - initio total energy calculations for metals and semiconductors using a plane-wave basis set [J ] . Computational Materials Science , 1996 , 6 ( 1 ): 15 - 50 .
Kresse G , Furthmuller J . Efficient iterative schemes for ab initio total-energy calculations using a plane-wave basis set [J ] . Phys. Rev. B Condens. Matter , 1996 , 54 ( 16 ): 11169-11186 .
Perdew J P , Burke K , Ernzerhof M . Generalized gradient approximation made simple [J ] . Physical Review Letters , 1996 , 77 ( 18 ): 3865 - 3868 .
Blöchl P E . Projector augmented-wave method [J ] . Phys. Rev. B Condens. Matter , 1994 , 50 ( 24 ): 17953-17979 .
Wang Z Y , Liang T S , Yang , Y P , et al . High chemisorption abilities of hydrogen and oxygen on ultrasmall iron clusters: a first-principles study [J ] . Chemical Physics Letters , 2018 , 705 : 59 - 64 .
杨晓丽 , 苏雄 , 杨小峰 , 等 . 负载型金属催化剂的热稳定机制 [J ] . 化工学报 , 2016 , 67 ( 1 ): 73 - 82 .
Yang X L , Su X , Yang X F , et al . Stabilization mechanism of supported metal catalyst [J ] . CIESC Journal , 2016 , 67 ( 1 ): 73 - 82 .
Yang X F , Wang A , Qiao B , et al . Single-atom catalysts: a new frontier in heterogeneous catalysis [J ] . Accounts of Chemical Research , 2013 , 46 ( 8 ): 1740 .
唐华浩 , 孙俊 , 李格升 , 等 . 乙醇预混层流火焰结构的模拟研究 [J ] . 武汉理工大学学报 , 2009 , 31 ( 2 ): 66 - 69 .
Tang H H , Sun J , Li G S , et al . Simulation research of 1D laminar premix flame [J ] . Journal of Wuhan University of Technology , 2009 , 31 ( 2 ): 66 - 69 .
秦先锋 , 袁银男 , 李仁春 , 等 . 正庚烷低压预混燃烧火焰中间产物生成特性分析 [J ] . 机械设计与制造 , 2014 , ( 3 ): 262 - 264 .
Qin X F , Yuan Y N , Li R C , et al . Combustion intermediate radical characteristics of n -heptane in a low-pressure premixed laminar flame [J ] . Machinery Design & Manufacture , 2014 , ( 3 ): 262 - 264 .