PENG Jiewei, MA Youfu, WU Hengliang, et al. Visualization study on flow pattern of gas-liquid two-phase flowing through multi-orifice plate in horizontal pipe[J]. CIESC Journal, 2017, (6): 2266-2274.
DOI:
PENG Jiewei, MA Youfu, WU Hengliang, et al. Visualization study on flow pattern of gas-liquid two-phase flowing through multi-orifice plate in horizontal pipe[J]. CIESC Journal, 2017, (6): 2266-2274.DOI: 10.11949/j.issn.0438-1157.20161726.
Visualization study on flow pattern of gas-liquid two-phase flowing through multi-orifice plate in horizontal pipe
Producing a bubble flow in multi-orifice plate downstream (MOPD) is a basic condition for the exhaust absorber with multi-orifice plates to achieve a satisfied absorption capacity. In this paper
a visualization experiment on the flow pattern of gas-liquid two-phase flowing through a multi-orifice plate in a horizontal pipe was conducted using the air and water as the gas and liquid phase
respectively. Four multi-orifice plates with the orifice diameter of 2
3
4 and 5 mm were tested in a horizontal plexiglass pipe with the inner diameter of 98.5 mm by using a high speed camcorder to record the air-water flow
thus the effects of orifice diameter
air flow rate and water flow rate on the flow pattern in the multi-orifice plate downstream were obtained. The results show that the stratified/plug flow transition in MOPD shift to an increased water flow rate while the plug/bubble flow transition shift to a decreased water flow rate in comparison with the flow pattern transition in horizontal pipes. The flow pattern in MOPD is inclined to a bubble flow with the decrease of air flow rate or the increase of water flow rate. Meanwhile
an important dependence on the orifice diameter is found for the flow pattern in MOPD. With the decrease of orifice diameter
the plug/bubble flow transition shift to an increased air flow rate and a decreased water flow rate
meaning that an increased flow range is obtained to form bubble flow. In addition
as the orifice diameter decreasing
the flow pattern in MOPD is inclined to transfer from wavy stratified flow to bubble flow directly without an occurrence of plug flow. To achieve a satisfied flow pattern and absorption capacity for the exhaust absorber with multi-orifice plates
it is recommended to choose the orifice diameter not larger than 3 mm.
Analysis of the effect of air injection hole position on bubble formation characteristics of Venturi-type microbubble generator
Migration behavior of bubble cluster emerging from micro-orifice with liquid cross flow in mini-channel
Gas-liquid flow distribution of parallel microchannels
Oxygen mass transfer performance of hollow fiber non-bubble aeration membrane based on gas/liquid-phase measurement method
Controlled synthesis of Bi2MoO6/MoO3 composite fibers via in-situ hydrothermal method and their high-efficiency photocatalytic hydrogen production performance
Related Author
Guodong DING
Jiaqing CHEN
Zhenlin LI
Xiaolei CAI
ZHU Xun
XIE Jian
WANG Hong
LIAO Qiang
Related Institution
College of Mechanical Engineering, Beijing Institute of Petrochemical Technology
College of Mechanical and Transportation Engineering, China University of Petroleum
Beijing Key Laboratory of Pipeline Critical Technology and Equipment for Deep Water Oil & Gas Development
Key Laboratory of Low-grade Energy Utilization Technologies and Systems, Chongqing University
Institute of Engineering Thermophysics, Chongqing University