ZHAO Mengyue, PENG Yongzhen, WANG Bo, et al. Achievement of long-term and stable partial nitritation in sequencing batch reactor[J]. CIESC Journal, 2016, (6): 2525-2532.
DOI:
ZHAO Mengyue, PENG Yongzhen, WANG Bo, et al. Achievement of long-term and stable partial nitritation in sequencing batch reactor[J]. CIESC Journal, 2016, (6): 2525-2532.DOI: 10.11949/j.issn.0438-1157.20151877.
Achievement of long-term and stable partial nitritation in sequencing batch reactor
a sequencing batch reactor (SBR) was used to treat domestic wastewater
and the optimal aeration rate and time to realize partial nitritation (PN
NH4+-N was partially converted to NO2--N) were obtained through three preliminary tests. A long-term PNSBR was operated more than 110 d (450 cycles) with an optimal aeration rate [7.2-12 L·(h·L)-1] and time (2-3 h) during aeration. The results showed that the nitrite accumulation rate in the effluent maintained 94%-100%
indicating the stable partial nitrification. The ratios between NO2--N and NH4+-N were in the range of 2-4. Further analysis demonstrated that in the long-term operation of PNSBR
the low dissolved oxygen (DO) by controlling aeration benefited the ammonia oxidizing bacteria (AOB) activity but inhibited the nitrite oxidizing bacteria (NOB) one. On the other hand
the residual nitrite after decanting in a cycle was removed via denitrification (endogenous in this cycle and exogenous in next cycle) by using organics in raw wastewater
through which substrates for NOB were prohibited
and thus stable PN was realized. The process of simultaneous anammox and denitrification (SAD) was widespread
Dissolved oxygen control of wastewater treatment process using self-organizing fuzzy neural network
Start-up of CANON process on domestic wastewater using intermittent aeration with low DO
Efficient organics utilization of low C/N ratio domestic sewage through partial nitritation SBR
Oxygen mass transfer performance of hollow fiber non-bubble aeration membrane based on gas/liquid-phase measurement method
Preparation of C3N4/MIL-125 (Ti) composite and its performance in photocatalytic reduction of Cr (Ⅵ)
Related Author
周红标
ZHANG Qian
WANG Shuying
MIAO Yuanyuan
WANG Xiaoxia
PENG Yongzhen
ZHAO Mengyue
WANG Bo
Related Institution
Faculty of Automation, Huaiyin Institute of Technology
National Engineering Laboratory for Advanced Municipal Wastewater Treatment and Reuse Technology, Engineering Research Center of Beijing, Beijing University of Technology
National Engineering Laboratory for Advanced Municipal Wastewater Treatment and Reuse Technology, Key Laboratory of Beijing for Water Quality Science and Water Environment Recovery Engineering, Beijing University of Technology
School of Civil Engineering and Transportation, Guangzhou University
Key Laboratory for Water Quality and Conservation of the Pearl River Delta, Ministry of Education