KONG Lingguang, LU Yi. Optimization analysis of booster-recondensation system in LNG receiving terminal[J]. CIESC Journal, 2015, (S2): 418-424.
DOI:
KONG Lingguang, LU Yi. Optimization analysis of booster-recondensation system in LNG receiving terminal[J]. CIESC Journal, 2015, (S2): 418-424.DOI: 10.11949/j.issn.0438-1157.20151063.
Optimization analysis of booster-recondensation system in LNG receiving terminal
Stable operation of booster-recondensation system is critical for liquefied natural gas(LNG)receiving terminal.This paper illustrates the process and control scheme of Booster-Recondensation System.Based on the high-pressure pump inlet filter blocking scenario
paper discussed the interaction between high-pressure pump suction pressure and the filter pressure difference.Meanwhile paper demonstrates the potential impact to recondenser operation due to pump well vent line piping design.Optimization is proposed for stable operation.