WANG Chenxing, REN Shuhang, HOU Yucui, et al. Absorption of SO2 in simulated flue gas with aqueous ionic liquid solutions[J]. CIESC Journal, 2015, (S1): 222-227. DOI: 10.11949/j.issn.0438-1157.20150156.
DOI:
WANG Chenxing, REN Shuhang, HOU Yucui, et al. Absorption of SO2 in simulated flue gas with aqueous ionic liquid solutions[J]. CIESC Journal, 2015, (S1): 222-227. DOI: 10.11949/j.issn.0438-1157.20150156.DOI:
Absorption of SO2 in simulated flue gas with aqueous ionic liquid solutions
A large-scale desulfurization device was designed and made to investigate the absorption of SO2 in simulated flue gas with aqueous ethanolamine lactate ([MEA]L) solutions at different conditions. The optimum conditions were found and circulatory SO2 absorption-desorption experiment was performed on the device. The results showed that the SO2 removal rate increased with an increase of water content of aqueous [MEA]L solution. The SO2 removal rate increased with a decrease of the molar ratio of gas to liquid absorbent G/L). When G/L is 420 and the concentrations of SO2 in flue gas are 2850—14280 mg·m-3
the output concentration of SO2 was under 285 mg·m-3
which conforms to the standard of flue gas issue. CO2 in the flue gas had no effect on absorption SO2 with aqueous [MEA]L solutions. Furthermore
the solution after SO2 absorption could be regenerated by stream stripping
and reused for absorbing SO2 with a high removal rate.