A strategy of membrane cleaning and replacing schedule for spiral-wound SWRO system
Membrane fouling is a key factor for the increase of operation cost and the decrease of product performance of the seawater reverse osmosis (SWRO) system. In this work
a strategy of new membrane cleaning and replacing schedule for spiral-wound SWRO system was proposed to reduce the operation cost. First
according to the solution-diffusion principle and membrane fouling characteristics
the SWRO performance model considering membrane fouling was established. Then
the total operation cost was integrated with membrane cleaning and replacing schedule to establish the optimization problem
which set minimizing the daily operation cost of the system as an objective
membrane cleaning frequency
cleaning time and replacing time as optimization variables
and the open equations as constraints. And the finite-element-based simultaneous method was applied to solve the complex optimization problem efficiently. After the case study and analysis of the SWRO system
the optimization results showed that the proposed optimization strategy can significantly reduce the operational cost
while obtaining the optimal membrane cleaning frequency and the cleaning and replacing time. It was found that the feed seawater temperature had an important effect on the membrane cleaning and replacing schedule as well as total operational cost
and thus it was not suitable to fix the membrane replacement interval. In addition
the proposed method can obtain the profile of optimal operational pressure and flow rate as well as internal status and performance of the system under different operation conditions
which was of great significance to optimize the operation of the system and the further study on the inner status of the system.