SHEN Xiangyang, DING Jing, LU Jianfeng. Numerical study of transient heat transfer performance for molten salt receiver tube[J]. CIESC Journal, 2020, 71(11): 5140-5149
SHEN Xiangyang, DING Jing, LU Jianfeng. Numerical study of transient heat transfer performance for molten salt receiver tube[J]. CIESC Journal, 2020, 71(11): 5140-5149DOI: 10.11949/0438-1157.20200221.
Numerical study of transient heat transfer performance for molten salt receiver tube
The heat transfer experimental system and mathematical model of receiver tube are established to analyze the transient heat transfer performance of molten salt with heat flux of outer wall sudden change
molten salt velocity sharp reduction
heat flux of outer wall and molten salt velocity sharp reduction at the same time. The results show that when the heat flow on the outer wall of the tube changes suddenly (sudden increase or decrease)
the temperature of the molten salt in the center of the tub
e at the inlet section of the heat absorption tube changes less
but the temperature of the tube wall changes faster. When the molten salt velocity sharp reduction
the outlet temperature of molten salt and the outer wall temperature increase with time
but the difference of outer wall and inner wall temperature decreases at first and then increases
when
t
≥16.0 s
each temperature and temperature difference reach steady state. When the heat flux on the outer wall of the heat absorption tube and the molten salt flow rate in the tube are halved at the same time
the temperature of the molten salt in the center and the outlet of the tube rises first and then decreases with the passage of time. After the steady state
the two molten salt temperatures maintain a constant value and are compared with the transient state. The corresponding molten salt temperature is close to initial starting temperature. The difference of outer wall and inner wall temperature after transient stability is proportional to the heat flux of outer wall
but which is independent of molten salt velocity. The outlet temperature equation of molten salt in receiver tube after transient stability is obtained
which provides a theoretical basis for the outlet temperature control of molten salt in receiver during the transient heat transfer process.
关键词
Keywords
references
Wang W J , Malmquist A , Aichmayer L , et al . Transient performance of an impinging receiver: an indoor experimental study [J ] . Energy Conversion and Management , 2018 , 158 : 193 - 200 .
He Y L , Wang K , Du B C , et al . Non-uniform characteristics of solar flux distribution in the concentrating solar power systems and its corresponding solutions: a review [J ] . Chinese Science Bulletin , 2016 , 61 : 3208 - 3237 .
Xu L , Stein W , Kim J , et al . Transient numerical model for the thermal performance of the solar receiver [J ] . Applied Thermal Engineering , 2018 , 141 : 1035 - 1047 .
Xu L , Stein W , Kim J , et al . Three-dimensional transient numerical model for the thermal performance of the solar receiver [J ] . Renewable Energy , 2018 , 120 : 550 - 566 .
Chen Z W , Wang Y S , Chen K T , et al . Numerical research on dynamic characteristics in solar cavity receiver based on step-change radiation flux [J ] . Journal of Engineering Thermophysics , 2012 , 33 ( 10 ): 1719 - 1722 .
Sheng L X , Li J Y , Zhao Y H . Modeling and dynamic simulation of receiver in a solar tower power station [J ] . CIESC Journal , 2016 , 67 ( 3 ): 736 - 742 .
Xu C , Liu D Y , Zheng Y , et al . Dynamic models research on a porous media receiver of solar tower power [J ] . Proceedings of the CSEE , 2010 , 30 ( 29 ): 122 - 127 .
Wu Z Y , Wang Z F . Fully coupled transient modeling of ceramic foam volumetric solar air receiver [J ] . Solar Energy , 2013 , 89 : 122 - 133 .
Wang F Q , Guan Z N , Tan J Y , et al . Transient thermal performance response characteristics of porous-medium receiver heated by multi-dish concentrator [J ] . International Communications in Heat and Mass Transfer , 2016 , 75 : 36 - 41 .
Ribeiro R R , de Lemos M J S . Transient behavior and thermal efficiency of volumetric heat receivers [J ] . International Journal of Heat and Mass Transfer , 2019 , 149 : 119 - 128 .
Najafabadi H A , Ozalp N , Ophoff C , et al . An experimental study on temperature control of a solar receiver under transient solar load [J ] . Solar Energy , 2019 , 186 : 52 - 59 .
Tu N , Fang J B , Wei J J . Numerical simulation of different start-up performance of a solar cavity receiver [J ] . Journal of Engineering Thermophysics , 2012 , 33 ( 11 ): 1900 - 1903 .
Zhang Q Q , Li X , Chang C , et al . Thermal performance analysis of molten salt cavity receivers under cloudy conditions [J ] . Proceedings of the CSEE , 2014 , 34 ( 8 ): 1291 - 1296 .
Zhang Q Q , Li X , Wang Z F , et al . Experimental and theoretical analysis of a dynamic test method for molten salt cavity receiver [J ] . Renewable Energy , 2013 , 50 : 214 - 221 .
Samanes J , Garcia-Barberena J . A model for the transient performance simulation of solar cavity receivers [J ] . Solar Energy , 2014 , 110 : 789 - 806 .
Schöttl P , Bern G , Rooyen D W V , et al . Efficient modeling of variable solar flux distribution on solar tower receivers by interpolation of few discrete representations [J ] . Solar Energy , 2018 , 160 : 43 - 55 .
Wang C H . Dynamic simulation of molten salt loop in solar tower thermal power plant [D ] . Shanghai : Shanghai Institute of Applied Physics , Chinese Academy of Sciences , 2018 .
Li Z , Zhang Q Q , Wang Z F , et al . Numerical and experimental study of solidification dangers in a molten salt receiver for cloudy conditions [J ] . Solar Energy , 2019 , 193 : 118 - 131 .
Crespi F , Toscani A , Zani P , et al . Effect of passing clouds on the dynamic performance of a CSP tower receiver with molten salt heat storage [J ] . Applied Energy , 2018 , 229 : 224 - 235 .
Fritsch A , Uhlig R , Marocco L , et al . A comparison between transient CFD and FEM simulations of solar central receiver tubes using molten salt and liquid metals [J ] . Solar Energy , 2017 , 155 : 259 - 266 .
Augsburger G , Favrat D . Modelling of the receiver transient flux distribution due to cloud passages on a solar tower thermal power plant [J ] . Solar Energy , 2013 , 87 : 42 - 52 .
Too Y C S , García J , Padilla R V , et al . A transient optical-thermal model with dynamic matrix controller for solar central receivers [J ] . Applied Thermal Engineering , 2019 , 154 : 686 – 698 .
García J , Too Y C S , Padilla R V , et al . Dynamic performance of an aiming control methodology for solar central receivers due to cloud disturbances [J ] . Renewable Energy , 2018 , 121 : 355 - 367 .
Terdalkar R , Doupis D , Clark M , et al . Transient simulation of high temperature high pressure solar tower receiver [J ] . Energy Procedia , 2015 , 69 : 1451 - 1460 .
Liu S W , Wu Y T , Cui W J , et al . Forced convection heat transfer with low-melting point molten salt in circular pipe [J ] . CIESC Journal , 2015 , 66 ( 2 ): 530 - 536 .
杨世铭 , 陶文铨 . 传热学 [M ] . 4版 . 北京 : 高等教育出版社 , 2018 .
Yang S M , Tao W Q . Heat Transfer [M ] . 4th ed . Beijing : Higher Education Press , 2108 .
Yang M L , Yang X X , Ding J , et al . Heat transfer research on molten salt receiver with semi-circumference heat [J ] . Acta Energiae Solaris Sinica , 2009 , 30 ( 8 ): 1007 - 1012 .
Lu J F , Shen X Y , Ding J , et al . Convective heat transfer of high temperature molten salt in transversely grooved tube [J ] . Applied Thermal Engineering , 2013 , 61 : 157 - 162 .
Lu J F , Shen X Y , Ding J , et al . Transition and turbulent convective heat transfer of molten salt in spirally grooved tube [J ] . Experimental Thermal and Fluid Science , 2013 , 47 : 180 - 185 .
Shen X Y , Zhang Q Z , Lu J F , et al . Unsteady convective heat transfer performances of molten salt in receiver tube [J ] . CIESC Journal , 2012 , 63 : 36 - 40 .
Heat transfer enhancement mechanism of phase change heat storage system based on two-dimensional gradient dendritic fins
Heat transfer characteristic of molten salt in transverse corrugated tube with semi-circumference heating
Performance investigation of sleeve tube heat exchanger filled with multi-layer phase change materials
A multiscale approach for the thermo-mechanical coupling analysis of parallel-flow PCHE core
Simulation research on the boiling heat transfer characteristics of liquid sodium under microgravity
Related Author
ZHANG Xinyu
YANG Xiaohong
ZHANG Yannan
XU Jiakun
GUO Xiao
TIAN Rui
LU Jianfeng
Ning WANG
Related Institution
School of Energy and Power Engineering, Inner Mongolia University of Technology
Key Laboratory of Wind and Solar Energy Utilization Technology, Ministry of Education
Inner Mongolia Key Laboratory of Renewable Energy
School of Energy and Power Engineering, University of Shanghai for Science and Technology,Shanghai Key Laboratory of Multiphase Flow and Heat Transfer in Power Engineering
MOE Key Laboratory of Thermo-Fluid Science and Engineering, Xi’an Jiaotong University, , Shaanxi