Heat Transfer and Flow Resistance in HighEfficient Tubular Heat Exchanger with GasFlows Parallel to Tube Bundles in Shell Side
|更新时间:2025-12-16
|
Heat Transfer and Flow Resistance in HighEfficient Tubular Heat Exchanger with GasFlows Parallel to Tube Bundles in Shell Side
CIESC JournalIssue 2, (1991)
作者机构:
华南理工大学化工研究所,华南理工大学化工研究所,华南理工大学化工研究所 ,广州,广州,广州
作者简介:
基金信息:
DOI:
CLC:
Online First:25 April 1991,
Published:25 April 1991
稿件说明:
移动端阅览
邓先和, 罗运禄, 邓颂九. Heat Transfer and Flow Resistance in HighEfficient Tubular Heat Exchanger with GasFlows Parallel to Tube Bundles in Shell Side[J]. CIESC Journal, 1991, (2).
DOI:
邓先和, 罗运禄, 邓颂九. Heat Transfer and Flow Resistance in HighEfficient Tubular Heat Exchanger with GasFlows Parallel to Tube Bundles in Shell Side[J]. CIESC Journal, 1991, (2).DOI:
Heat Transfer and Flow Resistance in HighEfficient Tubular Heat Exchanger with GasFlows Parallel to Tube Bundles in Shell Side
Investigation of heat transfer and flow resistance of tubular gas-gas heat exchanger with contracted-expanded tube bundles and spiral fluted tube bundles and air flowing parallel to tube bundles in the shell side is reported. Comparison of heat transfer performance was made between this type of tubular gas heat exchanger and the segment baffled tubular gas heat exchanger under the same conditions of total gas pressure drop in the tube and shell sides
total volume flow rate
temperature difference and rate of heat transfer. The results showed that the total heat transfer coefficient K of gas heat exchanger with contracted-expanded tube bundles was 64.8% higher than that of segment baffled tubular gas heat exchanger
and 40% of heat transfer surface area could be saved.