Gas Hold-up and Liquid Circulation in Gas-lift Loop Reactor with Annular Bubbling
In a laboratory-scale gas-lift loop reactor with annular bubbling
some hydrodynamic properties
such as gas hold-up in riser and liquid circulation were investigated. The drift flux model was used to study gas hold-up in riser. The relationship among εa
ug and u1 was established as follows: where um =ug +u1
Co = 1.58
vb = 30. 1cm/s. Based on the principle of minimum energy dissipation
the equation of liquid circulation was derived
that is
where K{= [2HgDe/(3λLe]0.5} is a structure parameter
which can be figured out by fitting the experimental data with the equation. According to this equation
the mechanism of circulation can be revealed. Furthermore
because of its general feature
the equation can be used for the description of liquid circulation in any gas-lift loop reactor.