Measurement of Tube Surface Temperature and Calculation of Geometric Factor
|更新时间:2025-12-16
|
Measurement of Tube Surface Temperature and Calculation of Geometric Factor
CIESC JournalIssue 3, (1983)
作者机构:
化工部化工机械研究院,化工部化工机械研究院,化工部化工机械研究院
作者简介:
基金信息:
DOI:
CLC:
Online First:25 September 1983,
Published:25 September 1983
稿件说明:
移动端阅览
Zhang Songlong, Zhen Xiulan and Zhuang ZhenwanChemical Machinery Research Institute, Ministry of Chemical Industry.. Measurement of Tube Surface Temperature and Calculation of Geometric Factor[J]. CIESC Journal, 1983, (3).
DOI:
Zhang Songlong, Zhen Xiulan and Zhuang ZhenwanChemical Machinery Research Institute, Ministry of Chemical Industry.. Measurement of Tube Surface Temperature and Calculation of Geometric Factor[J]. CIESC Journal, 1983, (3).DOI:
Measurement of Tube Surface Temperature and Calculation of Geometric Factor
it is necessary to make correction for tube surface temperature measured by pyrometer. Because the reflected radiation has much effect on this temperature
the geometric factor considering the reflected radiation is an important quantity in the temperature correction. This paper presents a new method for calculation of geometric factor F. Based on local angle coefficient
the geometric factor F is obtained by calculating the average angle coefficient in the circle of vision field. As an example
the geometric factors for the Topsφes converter and the Lummus cracking furnace have been calculated
and by comparison of the calculated values of geometric factors for the Topsφes converter with those suggested good agreement between them has been found. Based on the presented geometric factor in this paper
the corrected values for the measured temperature by pyrometer agrees with measured temperature by armor thermocouple.