Investigations on Branched Pipe Distributorsfor Fluidized Beds(Ⅱ) Determination of Design Parameters for Branched Pipe Distributors
|更新时间:2025-12-16
|
Investigations on Branched Pipe Distributorsfor Fluidized Beds(Ⅱ) Determination of Design Parameters for Branched Pipe Distributors
CIESC JournalIssue 3, (1984)
作者机构:
清华大学化学化工系,清华大学化学化工系,清华大学化学化工系,清华大学化学化工系
作者简介:
基金信息:
DOI:
CLC:
Online First:25 September 1984,
Published:25 September 1984
稿件说明:
移动端阅览
Jin Yong, Yu Zhiqing, Sun Zhufan and Peng BinpuDepartment nf Chemistry and Chemical Engineering, et al. Investigations on Branched Pipe Distributorsfor Fluidized Beds(Ⅱ) Determination of Design Parameters for Branched Pipe Distributors[J]. CIESC Journal, 1984, (3).
DOI:
Jin Yong, Yu Zhiqing, Sun Zhufan and Peng BinpuDepartment nf Chemistry and Chemical Engineering, et al. Investigations on Branched Pipe Distributorsfor Fluidized Beds(Ⅱ) Determination of Design Parameters for Branched Pipe Distributors[J]. CIESC Journal, 1984, (3).DOI:
Investigations on Branched Pipe Distributorsfor Fluidized Beds(Ⅱ) Determination of Design Parameters for Branched Pipe Distributors
The following design methods for determining the major parameters of branched pipe distributors have been studied in gas-solid fluidized beds for uniform gas distribution. 1. To describe the effect of varying mass flow of gas
a momentum equation was introduced: where K is the momentum recovery factor. An empirical formula for factor K is suggested as follows: K=0. 6041-0. 1561 2. For the proper arrangement of the ejector tube diameters along the branched pipes so as to attain a uniform gas distribution
the resistance coefficient
of the side flow ejector tube was studied
yielding the following relations. where and (for q/d>3.8) where Re>2300 Re<2300 3. A design procedure for this type of gas distributor systems has been developed and was illustrated with an example.