Heat transfer model and economic analysis on VIP and PU multiple-insulator applied to freezer
|更新时间:2025-12-10
|
Heat transfer model and economic analysis on VIP and PU multiple-insulator applied to freezer
CIESC JournalIssue S2, (2010)
作者机构:
1. 集美大学机械工程学院,福建省清洁燃烧和能源高效利用工程技术研究中心,福建,厦门,361021
2. 高特高新材料有限公司,福建,厦门,361021
作者简介:
基金信息:
DOI:
CLC:
Online First:30 December 2010,
Published:30 December 2010
稿件说明:
移动端阅览
庄友明. Heat transfer model and economic analysis on VIP and PU multiple-insulator applied to freezer[J]. CIESC Journal, 2010, (S2).
DOI:
庄友明. Heat transfer model and economic analysis on VIP and PU multiple-insulator applied to freezer[J]. CIESC Journal, 2010, (S2).DOI:
Heat transfer model and economic analysis on VIP and PU multiple-insulator applied to freezer
摘要
Abstract
A model for the heat transfer of vacuum insulation panel(VIP)and polyurethane foam(PU)multiple-insulator applied to freezer is established and the relationship between the heat flux and thickness of VIP under different total thickness of the multiple-insulator is analyzed.Five curves of heat flux versus thickness of VIP corresponding to five kinds of total thickness of multiple-insulator are presented through simulation.The energy-saving effect and economic benefits from the VIP+PU multiple-insulator applying to freezer are further analyzed and then the optimal thicknesses of VIP in multiple-insulator and its corresponding invest recall-period under different total thicknesses are obtained.It is revealed that all the optimal thicknesses of VIP nearly have the same value of 0.01 m.The shortest invest recall period for the application of the multiple-insulator instead of pure PU insulator to freezer is 3.7 years.