The presence of alternating current (AC) may cause serious damage on metal structures even when cathodic protection (CP) is applied and off-potential matches -850 mVCSE criterion. When pipelines are in the vicinity of a high AC electrical field
such as a power line or an electrical railway
this corrosion may occur at the location of coating holidays. Although AC corrosion of metal was only a fraction of an equivalent amount of direct current
but the corrosion damage cannot be ignored. For direct current (DC) corrosion on metal structures there is large agreement on criteria to be used for corrosion mitigation. AC corrosion mechanism is not yet understood and reliable techniques for the determination of the corrosion risk are not yet available. Therefore
the basic problems on AC corrosion should be investigated in detail. An overview of the AC induced metal corrosion is presented. Increasing number of cases and laboratory test results confirmed that AC corrosion risk really exists and it is a serious factor in corrosion of pipelines. Many studies indicate that a number of variables affect the severity of AC corrosion activity
e.g. AC frequency is one of the factors affecting corrosion rate. Investigations show that corrosion rate decreases with increasing frequency firstly
but with further increase of frequency up to a threshold corrosion rate increases. Several mechanism hypotheses of AC corrosion are presented
but without consensus regarding the mechanisms. There are several criteria to evaluate the probability of AC corrosion
which are based on the AC density or the ratio between AC density and DC density
or the AC voltages or the instantaneous off-potential
furthermore
the charges needed to oxidize corrosion produces on the corroded steel surface. However
criteria based solely on one indicator are inefficient. The comprehensive evaluation indicators system considers the balance between such induction effects as electrolyte environment and cathodic protection level