FLOW REGIMES AND STRATIFIED-WAVY FLOW EXPERIMENTAL CORRELATION OF CONDENSATION HEAT TRANSFER IN THREE-DIMENSIONAL MICROFIN TUBE
|更新时间:2025-12-10
|
FLOW REGIMES AND STRATIFIED-WAVY FLOW EXPERIMENTAL CORRELATION OF CONDENSATION HEAT TRANSFER IN THREE-DIMENSIONAL MICROFIN TUBE
CIESC JournalIssue 7, (2002)
作者机构:
重庆大学工程热物理研究所
作者简介:
基金信息:
DOI:
CLC:
Online First:25 July 2002,
Published:25 July 2002
稿件说明:
移动端阅览
CHEN Qinghua, XIN Mingdao. FLOW REGIMES AND STRATIFIED-WAVY FLOW EXPERIMENTAL CORRELATION OF CONDENSATION HEAT TRANSFER IN THREE-DIMENSIONAL MICROFIN TUBE[J]. CIESC Journal, 2002, (7).
DOI:
CHEN Qinghua, XIN Mingdao. FLOW REGIMES AND STRATIFIED-WAVY FLOW EXPERIMENTAL CORRELATION OF CONDENSATION HEAT TRANSFER IN THREE-DIMENSIONAL MICROFIN TUBE[J]. CIESC Journal, 2002, (7).DOI:
FLOW REGIMES AND STRATIFIED-WAVY FLOW EXPERIMENTAL CORRELATION OF CONDENSATION HEAT TRANSFER IN THREE-DIMENSIONAL MICROFIN TUBE
摘要
Abstract
Studies of two-phase flow patterns and their transitions during condensation have gained increasing interest because heat transfer characteristics are strongly dependent on flow patterns.Therefore
it is very important to know flow pattern inside a condenser at certain flow conditions and hence to develop heat transfer correlations consistent with the prevailing heat transfer mechanism in each flow pattern. The condensation heat transfer for R134a in two kinds of in-tube three-dimensional (3-D) microfin tubes with different geometries is investigated experimentally.In the range of experimental conditions
six distinguishable flow patterns (annular flow
semi-annular flow
stratified flow
wavy flow
slug flow and plug flow) are recorded by a video camera.The obtained results show that the flow regime transition criterion between annular flow and stratified-wavy flow decreases from Fr equal to 7 to Fr equal to 2 in the Soliman flow regime map.In stratified-wavy flow regime
the average heat transfer coefficients h of the two kinds of in-tube 3-D microfin tubes increase as mass flux increases and the number of microfins in 3-D microfin tube is not the controlling factor of condensation heat transfer performance.The regressed condensation heat transfer correlation from the experimental data of stratified-wavy flow regime is obtained.The disparity of the experimental data is within the limits of ±22%.Combined with the criteria of flow pattern transitions
the correlations can be used for the design of condenser of 3-D microfin tubes.