ELIMINATION OF REFLECT SHOCK WAVE IN OSCILLATORY TUBE
|更新时间:2025-12-10
|
ELIMINATION OF REFLECT SHOCK WAVE IN OSCILLATORY TUBE
CIESC JournalIssue 5, (2001)
作者机构:
1. 福州大学化工系
2. 大连理工大学化机系
作者简介:
基金信息:
DOI:
CLC:
Online First:25 May 2001,
Published:25 May 2001
稿件说明:
移动端阅览
LI Xuelai, ZHU Che. ELIMINATION OF REFLECT SHOCK WAVE IN OSCILLATORY TUBE[J]. CIESC Journal, 2001, (5).
DOI:
LI Xuelai, ZHU Che. ELIMINATION OF REFLECT SHOCK WAVE IN OSCILLATORY TUBE[J]. CIESC Journal, 2001, (5).DOI:
ELIMINATION OF REFLECT SHOCK WAVE IN OSCILLATORY TUBE
摘要
Abstract
A new concept
compound damp drip for absorbing shock wave in oscillatory tube
is developed in the present paper.The main idea of the concept is that the shock wave absorber must has the two functions
that is
it can not only exhaust the energy of the incident shock wave fully but also transfer the energy out promptly.In the experiment
the compound damp drip is structured with a multi-orifice for intensifying the energy dissipation of the shock wave and an internal cooling system for strengthening the heat transfer.The experimental results show that a strong reflect shock wave
whose strength is 66%of the incident shock wave
is measured at the position of the relative tube length x/L =0.3 when the oscillatory tube without the compound damp drip.But
after the compound damp drip is amounted at the closed end of the tube
the reflect shock wave is eliminated effectively and the refrigerating efficiency η is increased by 4%~10% in case of the L/d ratio is 140 and the expansion ratio ε is changed from 2.0 to 6.0.What is more
the refrigerating efficiency in case of L/d =140 and the tube is mounted with the compound damp drip is still higher by 2%~6% than that the tube without damp drip but L/d =300.The above result means that while the damp drip is used
the refrigerating efficiency can be increased and the size of the refrigerator can be decreased significantly.