Wang Hui, Xiao Bowen, Yuan Weikang(UNILAB Research Center of Chemical Reaction Engineering. THE BEHAVIOR OF HEAT REMOVAL UNSTEADY STATE SO_2 CONVERTERS(Ⅱ)──CONTROLLING PLAN FOR TWO-POINT HEAT REMOVAL CONVERTER[J]. CIESC Journal, 1998, (4).
DOI:
Wang Hui, Xiao Bowen, Yuan Weikang(UNILAB Research Center of Chemical Reaction Engineering. THE BEHAVIOR OF HEAT REMOVAL UNSTEADY STATE SO_2 CONVERTERS(Ⅱ)──CONTROLLING PLAN FOR TWO-POINT HEAT REMOVAL CONVERTER[J]. CIESC Journal, 1998, (4).DOI:
THE BEHAVIOR OF HEAT REMOVAL UNSTEADY STATE SO_2 CONVERTERS(Ⅱ)──CONTROLLING PLAN FOR TWO-POINT HEAT REMOVAL CONVERTER
the transfer function for converter regulation channel is determined.It is clear that the unsteady-state converter is a system of large time constant.Three converter controlling strategies for the treatment of tail gas of a factory are compared
from which the position control by valve is chosen owing to its easy operation and good control effect.