Removal behaviors of biological phosphorus (P)and nitrogen (N)in real domestic sewage with low C/N ratio were studied in a laboratory-scaled anaerobic/anoxic/oxic (A2/O)-biological aerated filter(BAF) combined system.In order to improve removal efficiency of the combined system
short sludge retention time (SRT)was applied in A2/O
which was favorable for P removal and denitrification
while longer SRT used in biological aerated filter (BAF)
which was favorable for polyphosphate-accumulating organisms(PAOs)and for nitrification to remove the ammonium nitrogen.The recycled liquid involving nitrate from BAF provided electron acceptor enough for the anoxic-zones of A2/O and necessary condition for de-phosphorus by denitrifying.Experimental results showed that with these operations in this combined system COD
N and P could be removed simultaneously.At conditions of HRT 7.5 h
SRT 15 d
the recycling ratio of liquid 400%
the concentrations of COD
ammonium nitrogen
total nitrogen (TN)and total phosphorus(TP)could be reduced from at average values of 376
67.9
72.9 and 6.1 mg·L-1 in the raw waste water to 42
0.86
9.6 and 0.1 mg·L-1 in the effluent
respectively.The rate of phosphorus removal by denitrifying were 1.49 and 1.64 g TP·(