Numerical simulations on characteristics of heat transfer and flow resistance in air cooler with oblique-cut semi-elliptic cylinder shell
|更新时间:2025-12-10
|
Numerical simulations on characteristics of heat transfer and flow resistance in air cooler with oblique-cut semi-elliptic cylinder shell
CIESC JournalIssue 5, Pages: 1252-1257(2011)
作者机构:
华北电力大学能源动力与机械工程学院,北京,102206
作者简介:
基金信息:
DOI:
CLC:
Online First:05 May 2011,
Published:05 May 2011
稿件说明:
移动端阅览
GAO Meng, ZHOU Guobing. Numerical simulations on characteristics of heat transfer and flow resistance in air cooler with oblique-cut semi-elliptic cylinder shell[J]. CIESC Journal, 2011, (5): 1252-1257.
DOI:
GAO Meng, ZHOU Guobing. Numerical simulations on characteristics of heat transfer and flow resistance in air cooler with oblique-cut semi-elliptic cylinder shell[J]. CIESC Journal, 2011, (5): 1252-1257.DOI:
Numerical simulations on characteristics of heat transfer and flow resistance in air cooler with oblique-cut semi-elliptic cylinder shell
The characteristics of heat transfer and flow resistance on the air side in a finned circular-tube air-cooler with a pair of oblique-cut semi-elliptic cylinder shells or delta winglets behind circular-tubes were investigated numerically.In-line and staggered arrangements of two rows of circular-tubes in the air cooler were considered
separately.The Reynolds number of the air flow ranged from 400 to 2200.The heat transfer enhancement and flow resistance of these two vortex generators were compared by using the comprehensive performance factor R=(j/j0)/(f/f0).The results show that the two vortex generators have almost the same heat transfer enhancement performance.However
due to the streamlined design of oblique-cut semi-elliptic cylinder shells
the corresponding flow resistances in the air coolers with in-line and staggered tubes are 0.07%—2.53% and 1.51%—5.31% lower than those of delta winglets
respectively.The two vortex generators have better effect on flow resistance reduction in the air cooler with staggered tubes at higher Reynolds numbers.The reduction of oblique-cut semi-elliptic cylinder shells is 6.40% at most and that of delta winglets is 4.39%.The R value of oblique-cut semi-elliptic cylinder shells is 0.68%—4.36% higher than that of delta winglets in the air cooler with in-line tubes for Re>700
and it is 0.79%—4.78% higher in the air cooler with staggered tubes.Moreover
the R value of oblique-cut semi-elliptic cylinder shells in the air cooler with staggered tubes is 3.11%—28.38% higher than that with in-line tubes.