Microbubbles are defined as bubbles with diameters less than 50 μm.Microbubbles have many advantages
such as huge interfacial area
low rising velocity in liquid phase
high inner pressure and fast dissolution.In this study
an accelerator was developed
and a system consisted of a conventional water pump and the accelerator was used as a microbubble aerator
with the expectation that it could be low in cost and easy to scale up.The produced microbubbles had a mean count diameter of less than 40 μm.In the experiments of 20 L volume
when the liquid flow rate was 20 L·min-1 and the gas flow rate was 2.67 L·min-1
the mass transfer coefficient of oxygen was more than 1.7 min-1 and the oxygen utilization efficiency was higher than 42%.Higher temperature was good for the mass transfer from the gas phase to the liquid phase.In the pilotscale study of 90 L volume
a mass transfer coefficient of more than 0.18 min-1 and an oxygen utilization efficiency of more than 27% were achieved at a liquid flow rate of more than 14 L·min-1 and the gas flow rate of lower than 2 L·min-1.Compared with the Nikuni system
this system allows higher gas flux
generates smaller microbubbles
consumes less energy and performs better in mass transfer and oxygensupply capacity.
Analysis of flow field characteristics and mixing performance of different SK-type static mixers
Study on impact of impurities in coal chemical waste salt on solvation of NaCl and Na2SO4
Research on the characterization of the molecular weight and its distribution of perfluoropolyether
Controlled synthesis of Bi2MoO6/MoO3 composite fibers via in-situ hydrothermal method and their high-efficiency photocatalytic hydrogen production performance
The impact of novel flow channel structure with sudden-expansion ratio on seawater-activated battery