Pressure drop model of multicyclone separator at high-pressure
|更新时间:2025-12-10
|
Pressure drop model of multicyclone separator at high-pressure
CIESC JournalIssue 9, Pages: 2424-2429(2010)
作者机构:
1. 中国石油大学机电工程学院
2. 中油管道机械制造有限责任公司
3. 浙江大学能源工程学系
作者简介:
基金信息:
DOI:
CLC:
Online First:05 September 2010,
Published:05 September 2010
稿件说明:
移动端阅览
XIONG Zhiyi, WU Xiaolin, YANG Yunlan, et al. Pressure drop model of multicyclone separator at high-pressure[J]. CIESC Journal, 2010, (9): 2424-2429.
DOI:
XIONG Zhiyi, WU Xiaolin, YANG Yunlan, et al. Pressure drop model of multicyclone separator at high-pressure[J]. CIESC Journal, 2010, (9): 2424-2429.DOI:
Pressure drop model of multicyclone separator at high-pressure
Based on concluding the pressure drop models of single and multicyclone separator under atmosphere pressure,and on-site measurement pressure drop values,a pressure drop model has been built up to predict and calculate the pressure drops for multicyclone separators operating at different pressures and temperatures in natural gas transportation.The reliability of pressure drop models has been calibrated by experiments,the results showed that the pressure drop models could calculate exactly the pressure drop values for corresponding cyclone separators,and the differences of pressure drop values between calculated by models and measured by experiments could be ignored.Therefore,the pressure drop model of multicyclone separator at high-pressure can be used to calculate the pressure drop values for multicyclone separators under different pressures and temperatures.