Transfer study of Cu(Ⅱ) through hollow fiber renewal liquid membrane with LIX984N as carrier
|更新时间:2025-12-10
|
Transfer study of Cu(Ⅱ) through hollow fiber renewal liquid membrane with LIX984N as carrier
CIESC JournalIssue 7, Pages: 1777-1782(2010)
作者机构:
北京化工大学化工资源有效利用国家重点实验室
作者简介:
基金信息:
DOI:
CLC:
Online First:05 July 2010,
Published:05 July 2010
稿件说明:
移动端阅览
YANG Yanqiang, REN Zhongqi, LIU Junteng, et al. Transfer study of Cu(Ⅱ) through hollow fiber renewal liquid membrane with LIX984N as carrier[J]. CIESC Journal, 2010, (7): 1777-1782.
DOI:
YANG Yanqiang, REN Zhongqi, LIU Junteng, et al. Transfer study of Cu(Ⅱ) through hollow fiber renewal liquid membrane with LIX984N as carrier[J]. CIESC Journal, 2010, (7): 1777-1782.DOI:
Transfer study of Cu(Ⅱ) through hollow fiber renewal liquid membrane with LIX984N as carrier
The transport of copper ion through a hollow fiber renewal liquid membrane was studied with LIX984N as the carrier
kerosene as the diluent and H2SO4 as the stripping. The experiments were conducted as functions of pressure difference
copper concentration in feed and stripping solutions
flow rate of both sides
operation mode
effective length of the hollow fibers module
etc. The results showed that the pressure difference between shell side and lumen side fluid had little influence on the mass transfer performance of the hollow fiber renewal liquid membrane process. The mass transfer flux increased with the increasing copper concentration in the feed solution. The copper concentration in the stripping solution had almost no influence on the mass transfer. The mass transfer flux increased with the increasing flow rate of feed phase on the shell side
while the flow rate of stripping phase on the lumen side had slight influence on the mass transfer. The effect of both operation modes of countercurrent and cocurrent flow on the mass transfer was slight. The average mass transfer flux per area decreased with the increasing effective length of hollow fibers.