Modeling and optimization of slurry wet pipeline transportation system in fluidized bed boiler
|更新时间:2025-12-10
|
Modeling and optimization of slurry wet pipeline transportation system in fluidized bed boiler
CIESC JournalIssue 8, Pages: 1882-1888(2010)
作者机构:
1. 杭州电子科技大学自动化研究所,浙江,杭州,310018
2. 兖矿峄山化工有限公司, 山东 邹城,273500
3. 山东华聚能源济二矿电厂,山东,济宁,272072
4. 邹城博达电力自动化工程有限公司, 山东 邹城,273500
作者简介:
基金信息:
DOI:
CLC:
Online First:05 August 2010,
Published:05 August 2010
稿件说明:
移动端阅览
JIANG Aipeng, JIANG Zhoushu, WANG Chunlin, et al. Modeling and optimization of slurry wet pipeline transportation system in fluidized bed boiler[J]. CIESC Journal, 2010, (8): 1882-1888.
DOI:
JIANG Aipeng, JIANG Zhoushu, WANG Chunlin, et al. Modeling and optimization of slurry wet pipeline transportation system in fluidized bed boiler[J]. CIESC Journal, 2010, (8): 1882-1888.DOI:
Modeling and optimization of slurry wet pipeline transportation system in fluidized bed boiler
It is the most effective resource use practices for slurry and slime to be used as fuel for power generation.The wet slurry pipeline transportation is an important part for the process of power generation
and there are design and operational optimization issues when pipeline transportation system was used .In order to achieve system optimization and energy conservation
the slurry wet pipeline transportation system model and the boiler heat utilization model were established based on rheological properties of slurry transportation
slurry heat and fluidized bed boiler combustion characteristics.Then an integrated optimization objective function based on power consumption cost and slurry consumption cost was established.The whole optimal problem was optimized by nonlinear optimization algorithm of SQP.Finally
with the consideration of parameters such as slurry price
wet slurry pipeline transports distance
power consumption
and other parameters which can impact the optimization objective
analysis and optimization calculations were carried out to obtain the detail results.The research results and present findings are of important significance to the operational optimization and energy conservation of fluidized bed boiler.