Safe and effective reaction condition is one of the important issues in green chemical technologyParametric sensitivity and thermal runaway behavior in non-adiabatic fixed bed reactors were analyzed by using a reaction kinetics model for ortho-xylene oxidation.The sensitivity of thermal behavior in a nonadiabatic fixed bed reactor was also examined with respect to cooling medium flow rate
feeding temperature and initial pressure.The simulation results showed that the non-adiabatic fixed bed reactor became extremely sensitive to small changes in cooling medium flow rate
feeding temperature and initial pressure when the reactor was operated in the sensitivity region of parameter space.The divergence (div) of the system was used to calculate the critical operating parameters and similar results were obtained in comparison with the criteria of literatureHowever
the divergence method was simpler than the existing criteria.Finally
the influence of cooling medium was taken into consideration to modify the div criterion
and more exact thermal runaway critical operating parameters were obtained.This criterion could provide good reference for reactor design and process control.