the solid desiccation system has more and more applications. However
the regeneration of the system is beset with high operating cost and complicated equipment. In this study a new electro-osmotic regeneration method was proposed
and the feasibility was explored experimentally. An electro-osmotic regeneration system with a sample box
controlling and measuring apparatus was set up
and its performance was evaluated. In the experiment
an obvious electro-osmotic regeneration effect was observed for the solid to desiccant in the humid air at normal temperature
and the maximum regeneration rate reached 0. 21 g·m-2·s-1. It was found that the whole electro-osmosis process was divided into three phases because of the Joule heating effect and electrode corrosion
which hindered the electro-osmotic regeneration. The experiment showed that the Joule heating effect could be reduced by controlling the supplied electric field at the initial stage.