Experiment and analysis of visualization and heat transfer of MPP condensers
|更新时间:2025-12-10
|
Experiment and analysis of visualization and heat transfer of MPP condensers
CIESC JournalIssue 8, Pages: 1932-1937(2009)
作者机构:
1. 重庆大学动力学院,重庆,400030
2. 艾泰斯热系统研发(上海)有限公司,上海,200233
3. 南方英特空调有限公司,重庆,400060
作者简介:
基金信息:
DOI:
CLC:
Online First:05 August 2009,
Published:05 August 2009
稿件说明:
移动端阅览
TONG Mingwei, YE Liang, ZENG Xin, et al. Experiment and analysis of visualization and heat transfer of MPP condensers[J]. CIESC Journal, 2009, (8): 1932-1937.
DOI:
TONG Mingwei, YE Liang, ZENG Xin, et al. Experiment and analysis of visualization and heat transfer of MPP condensers[J]. CIESC Journal, 2009, (8): 1932-1937.DOI:
Experiment and analysis of visualization and heat transfer of MPP condensers
Based on the heat transfer analysis of two-phase zone augmentation technique employed in multiple parallel-pass (MPP) condenser
visualization and performance tests are employed to compare and evaluate the performance of MPP condenser by referencing a same-sized parallel flow(PF) condenser as a baseline sample.Visual observation by using a high-speed camera indicates that a more uniform refrigerant quality entering the next cooling pass can be achieved in MPP condenser because superheat vapor through a pass-through hole on flow distributor directly injects into a liquid -vapor zone in a header tube.In addition
analytical and test results show MPP condenser
being designed to enlarge two-phase condensing zone
is able to improve cooling performance as high as 9.6% while its refrigerant mass flow increases as high as 13.34% when comparing with a benchmark PF condenser.