Glass transition temperature of polymers in supercritical carbon dioxide
|更新时间:2025-12-10
|
Glass transition temperature of polymers in supercritical carbon dioxide
CIESC JournalIssue 1, Pages: 254-259(2009)
作者机构:
1. 浙江大学生物医学工程与仪器科学学院
2. 浙江工业大学化工与材料科学学院
3. Department of Chemical Engineering, University of Waterloo,Canada
作者简介:
基金信息:
DOI:
CLC:
Online First:05 January 2009,
Published:05 January 2009
稿件说明:
移动端阅览
YE Shuming, JIANG Kai, JIANG Chunyue, et al. Glass transition temperature of polymers in supercritical carbon dioxide[J]. CIESC Journal, 2009, (1): 254-259.
DOI:
YE Shuming, JIANG Kai, JIANG Chunyue, et al. Glass transition temperature of polymers in supercritical carbon dioxide[J]. CIESC Journal, 2009, (1): 254-259.DOI:
Glass transition temperature of polymers in supercritical carbon dioxide
A novel apparatus for in situ optical measurement of glass transition temperature (Tg)was developed.The apparatus consisted of a high-pressure cell equipped with quartz windows
a data acquisition system
a heating and temperature-controlling system
a pressure-controlling system
and a CO2 feeding system.The volume changes of poly-(ethylene-terephthalate) (PET) when it was swollen by CO2 were measured in real-time by the apparatus
at the temperatures of 50
60
70
80
90
100 and 120℃
and under the pressures of 0.1
5
10
15
20 MPa of CO2.Consequently
the glass transition temperatures in SC-CO2 were obtained under various conditions as indicated above.To examine the accuracy and reliability of this method
comparison of the results obtained by the apparatus under atmospheric pressure with those obtained by the standard differential scanning calorimetry (DSC) were made
and these two methods produced results within acceptable precision (1.6%).Thus the method developed in this work can be reliably used to measure the glass transition temperature of polymers in SC-CO2.