Thermodynamic analysis on mixed refrigerant cycle of small scale natural gas liquefaction process in skid-mounted package
|更新时间:2025-12-10
|
Thermodynamic analysis on mixed refrigerant cycle of small scale natural gas liquefaction process in skid-mounted package
CIESC JournalIssue S2, Pages: 53-59(2008)
作者机构:
1. 集美大学机械工程学院,福建,厦门,361021
2. 上海交通大学制冷与低温工程研究所,上海,200240
作者简介:
基金信息:
DOI:
CLC:
Online First:30 December 2008,
Published:30 December 2008
稿件说明:
移动端阅览
CAO Wensheng, WU Jiying, LU Xuesheng, et al. Thermodynamic analysis on mixed refrigerant cycle of small scale natural gas liquefaction process in skid-mounted package[J]. CIESC Journal, 2008, (S2): 53-59.
DOI:
CAO Wensheng, WU Jiying, LU Xuesheng, et al. Thermodynamic analysis on mixed refrigerant cycle of small scale natural gas liquefaction process in skid-mounted package[J]. CIESC Journal, 2008, (S2): 53-59.DOI:
Thermodynamic analysis on mixed refrigerant cycle of small scale natural gas liquefaction process in skid-mounted package
how the key parameters of mixed refrigerant cycle of small scale natural gas liquefaction process in skid-mounted package affect the process performance (including specific power consumption
liquefaction rate
specific refrigerant flowrate and specific cooling water charge) is labored from thermodynamic point of view.These key parameters include temperature of separator S1 and S2
pressure of mixed refrigerant
inlet pressure of natural gas and storage pressure of LNG
components of natural gas and mixed refrigerant.The optimizer of original mode in Aspen HYSYS is used to optimize SP-MRC (mixed refrigerant cycle in skid-mounted package) and find the operating conditions which minimize LNG specific power consumption (objective function).The research reveals that the change of temperature
pressure and component fraction at the same time will influence the process performance remarkably.The new SP-MRC adopts the technology of integral incorporated cascade which combines heavy and light hydrocarbon.It can reduce the quantity and volume of compressors and heat exchangers in the guarantee of higher liquefaction rate and lower specific power consumption.