The industrial acetylene hydrogenation system has the characteristics of nonlinearity and slow parameter variance.The model
which is applied to model predictive control currently
is so simple that the predictive control result could not achieve the optimal effect during a long-term operation.So it is necessary to establish an accurate model of reactor as the virtual instrument in laboratory.Based on the model
it is possible to further study the more effective control method.In this paper
a heterogeneous
two-dimensional and dynamic model for an industrial acetylene hydrogenation system was developed through process analysis.The condition for activity loss with time
due to hydrocarbon deposition resulting from acetylene green oils
was also considered.The dynamic process simulation software gPROMS was utilized to perform its simulation
and the dynamic process could predict the changing trend.The effects of important parameters on the system simulation were analyzed
and a group of parameter values were chosen for the reactor which was studied in this paper.By linearizing the dynamic model at different operation points
the different latent roots of the linear state space model were obtained and used to analyze the system stability at different operation points.The simulation and stability analysis showed that the reactor was under control.