Gas volume fraction metering with U tube in low pressure annular-mist and wispy annular two-phase flow
|更新时间:2025-12-10
|
Gas volume fraction metering with U tube in low pressure annular-mist and wispy annular two-phase flow
CIESC JournalIssue 5, Pages: 1131-1135(2008)
作者机构:
天津大学电气与自动化工程学院
作者简介:
基金信息:
DOI:
CLC:
Online First:05 May 2008,
Published:05 May 2008
稿件说明:
移动端阅览
FANG Lide, ZHANG Tao, XU Ying, et al. Gas volume fraction metering with U tube in low pressure annular-mist and wispy annular two-phase flow[J]. CIESC Journal, 2008, (5): 1131-1135.
DOI:
FANG Lide, ZHANG Tao, XU Ying, et al. Gas volume fraction metering with U tube in low pressure annular-mist and wispy annular two-phase flow[J]. CIESC Journal, 2008, (5): 1131-1135.DOI:
Gas volume fraction metering with U tube in low pressure annular-mist and wispy annular two-phase flow
A measurement model of gas volume fraction(GVF) was deduced based on the energy equation,and the relationship of friction pressure drop between two vertical sections of U tube was considered.The measurement errors were investigated through experiment under low pressure annular-mist and wispy annular two-phase flow.The effects of gas mass friction,gas volume friction and flux density on gas volume fraction were analyzed and gas volume fraction was corrected with flux density.This correction improved the accuracy of gas volume fraction,and the correction method was verified through another independent test.