Particle flow behavior and restriction in back-mixing region of riser-fluidized bed coupled reactor
|更新时间:2025-12-10
|
Particle flow behavior and restriction in back-mixing region of riser-fluidized bed coupled reactor
CIESC JournalIssue 4, Pages: 859-865(2008)
作者机构:
中国石油大学(北京)重质油国家重点实验室,北京,102249
作者简介:
基金信息:
DOI:
CLC:
Online First:05 April 2008,
Published:05 April 2008
稿件说明:
移动端阅览
WANG Dewu, LU Chunxi. Particle flow behavior and restriction in back-mixing region of riser-fluidized bed coupled reactor[J]. CIESC Journal, 2008, (4): 859-865.
DOI:
WANG Dewu, LU Chunxi. Particle flow behavior and restriction in back-mixing region of riser-fluidized bed coupled reactor[J]. CIESC Journal, 2008, (4): 859-865.DOI:
Particle flow behavior and restriction in back-mixing region of riser-fluidized bed coupled reactor
A large-scale cold model experimental setup of a riser-fluidized bed coupled reactor was established according to olefin reduction technology with auxiliary reactor for FCC naphtha upgrading.The particle flow behavior in the outlet region of the riser section was experimentally investigated in the setup.Furthermore
the restriction index Ri
the ratio between real and theoretical averaged cross-sectional solid holdups in the particle back-mixing region section
was defined to quantitatively show the restriction effect of the riser outlet distributor and upper fluidized bed on the particle flow behavior in this region.The experimental results showed that
compared with the conventional riser
there existed a particle back-mixing region in the riser outlet of the coupled reactor.The length of the particle back-mixing region was related to the superficial gas velocity
solids flux and the solids bed level in the upper fluidized bed.The maximum local solids holdup in the particle back-mixing region close to the riser outlet appeared at the non-dimensional radial position Φ=0.7 at a lower superficial gas velocity and a higher solids flux. This was because an inverted taper gas-solid distributor was mounted at the riser outlet.The restriction index tended to increase with the axial position increasingly close to the riser outlet.At the same time
the restriction effect of the gas-solid distributor and upper fluidized bed on the gas-solid flow behavior was also gradually enhanced.