Factors affecting amount of activated carbon injection for flue gas mercury control
|更新时间:2025-12-10
|
Factors affecting amount of activated carbon injection for flue gas mercury control
CIESC JournalIssue 11, Pages: 2172-2177(2005)
作者机构:
浙江大学能源清洁利用与环境工程教育部重点实验室,浙江,杭州,310027
作者简介:
基金信息:
DOI:
CLC:
Online First:25 November 2005,
Published:25 November 2005
稿件说明:
移动端阅览
HU Changxing, ZHOU Jinsong, LUO Zhongyang, et al. Factors affecting amount of activated carbon injection for flue gas mercury control[J]. CIESC Journal, 2005, (11): 2172-2177.
DOI:
HU Changxing, ZHOU Jinsong, LUO Zhongyang, et al. Factors affecting amount of activated carbon injection for flue gas mercury control[J]. CIESC Journal, 2005, (11): 2172-2177.DOI:
Factors affecting amount of activated carbon injection for flue gas mercury control
flue gas temperature and particulate control device on the amount of activated carbon injection were investigated through the pilot-scale tests.The results showed that a greater amount of active carbon injection for mercury removal was needed at lower Hg concentration.Residence time was one of the critical factors affecting mercury removal.A longer residence time would increase the availability of activated carbon.On the other hand
increased injection of activated carbon would not result in the corresponding increase of mercury removal efficiency at a short residence time.Flue gas temperature had a negative influence on activated carbon mercury removal.However
activated carbon treated with chemical agents had a good performance at a high temperature. The fabric filter would be very helpful for activated carbon mercury removal and could decrease the amount of activated carbon injection.