Frequency analysis of acoustic emission and application in gas-solid fluidized bed
|更新时间:2025-12-10
|
Frequency analysis of acoustic emission and application in gas-solid fluidized bed
CIESC JournalIssue 8, Pages: 1474-1478(2005)
作者机构:
浙江大学化学工程系,浙江,杭州,310027
作者简介:
基金信息:
DOI:
CLC:
Online First:25 August 2005,
Published:25 August 2005
稿件说明:
移动端阅览
HOU Linxi, WANG Jingdai, YANG Yongrong, et al. Frequency analysis of acoustic emission and application in gas-solid fluidized bed[J]. CIESC Journal, 2005, (8): 1474-1478.
DOI:
HOU Linxi, WANG Jingdai, YANG Yongrong, et al. Frequency analysis of acoustic emission and application in gas-solid fluidized bed[J]. CIESC Journal, 2005, (8): 1474-1478.DOI:
Frequency analysis of acoustic emission and application in gas-solid fluidized bed
A model of signal main-frequency measurement was presented for the gas-solid fluidized bed to represent the quantitative relation of main-frequency and particle size
temperature
Young’s modulus and density. The acoustic emission(AE) measurement was completely non-intrusive and not affected by the background noises
and caused to human harm.The experiment based on AE measurement was performed by using a fast Fourier transform (FFT) analyzer in this study. It was found the signals main-frequency decreased with the increasing particle size
temperature
Young〖DK〗’s modulus and density. The experiment in the fluidized bed with i.d. of 150 mm showed that satisfactory agreement was obtained between calculated and experimental data with respect of the main-frequency (LLDPE
HDPE and bimodal polyethylene)
and the average errors were all less than 8.3%. The scale-up feasibility of the technical process was discussed by adjusting the elastic partameter. When the AE signals main-frequency model was applied to the industrial fluidized bed of LLDPE
HDPE
bimodal polyethylene
the mean errors between calculated and experimental data were 3.9%,8.2% and 8.8% respectively. By the criterion of the sharp decrease of main-frequency and the sharp increase of amplitude
a novel approach could be developed to judge whether the fluidization runs stably
and it could replace the γ-ray measurement in the future.