Droplet size of two-fluid airblast atomizer with large water/air mass flux ratio
|更新时间:2025-12-10
|
Droplet size of two-fluid airblast atomizer with large water/air mass flux ratio
CIESC JournalIssue 8, Pages: 1462-1466(2005)
作者机构:
华东理工大学资源与环境工程学院,上海,200237
作者简介:
基金信息:
DOI:
CLC:
Online First:25 August 2005,
Published:25 August 2005
稿件说明:
移动端阅览
LIU Haifeng, LI Weifeng, CHEN Mouzhi, et al. Droplet size of two-fluid airblast atomizer with large water/air mass flux ratio[J]. CIESC Journal, 2005, (8): 1462-1466.
DOI:
LIU Haifeng, LI Weifeng, CHEN Mouzhi, et al. Droplet size of two-fluid airblast atomizer with large water/air mass flux ratio[J]. CIESC Journal, 2005, (8): 1462-1466.DOI:
Droplet size of two-fluid airblast atomizer with large water/air mass flux ratio
Based on the finite stochastic breakup model (FSBM) of the airblast atomization process presented
the atomization process of coaxial two-fluid airblast atomizer with a large water/air mass flux ratio was investigated by using droplet breakup time and motion characteristics of droplet in air streams.The equation of Sauter mean diameter (SMD) with air jet velocity
water jet velocity and diameter
and water/air mass flux ratio was obtained.The experimental results of six coaxial two-fluid airblast atomizers with air and water were obtained by Malvern laser particle sizer of type 3600 measurement.The parameters in the equation of SMD were estimated according to the experimental results.The results showed that the theoretical analysis was reasonable and the relationship of SMD could be used to predict the SMD of coaxial two-fluid airblast atomizer with a large water/air mass flux ratio.