FLOW AND HEAT TRANSFER CHARACTERISTICS IN SHELL SIDE OF SHELL-AND-TUBE HEAT EXCHANGERS WITH SEPARATED BAFFLES PARALLEL TO SEGMENTAL BAFFLES
|更新时间:2025-12-10
|
FLOW AND HEAT TRANSFER CHARACTERISTICS IN SHELL SIDE OF SHELL-AND-TUBE HEAT EXCHANGERS WITH SEPARATED BAFFLES PARALLEL TO SEGMENTAL BAFFLES
CIESC JournalIssue 2, Pages: 275-279(2004)
作者机构:
华南理工大学教育部传热强化与过程节能重点实验室,广东,广州,510640
作者简介:
基金信息:
DOI:
CLC:
Online First:25 February 2004,
Published:25 February 2004
稿件说明:
移动端阅览
WANG Yangjun, DENG Xianhe, CHEN Ying, et al. FLOW AND HEAT TRANSFER CHARACTERISTICS IN SHELL SIDE OF SHELL-AND-TUBE HEAT EXCHANGERS WITH SEPARATED BAFFLES PARALLEL TO SEGMENTAL BAFFLES[J]. CIESC Journal, 2004, (2): 275-279.
DOI:
WANG Yangjun, DENG Xianhe, CHEN Ying, et al. FLOW AND HEAT TRANSFER CHARACTERISTICS IN SHELL SIDE OF SHELL-AND-TUBE HEAT EXCHANGERS WITH SEPARATED BAFFLES PARALLEL TO SEGMENTAL BAFFLES[J]. CIESC Journal, 2004, (2): 275-279.DOI:
FLOW AND HEAT TRANSFER CHARACTERISTICS IN SHELL SIDE OF SHELL-AND-TUBE HEAT EXCHANGERS WITH SEPARATED BAFFLES PARALLEL TO SEGMENTAL BAFFLES
A shell-and-tube heat exchanger with separated baffles parallel to segmental baffles was proposed
and an investigation on velocity distribution
heat transfer and flow resistance characteristics in the shell side of the proposed heat exchanger and traditional single segmental baffled shell-and-tube heat exchanger was reported. After the experiment
the empirical relations of heat transfer and flow resistance were obtained. The heat transfer enhancement comprehensive evaluation factor η was in the range from 1.15 to 1.20 for Reynolds number (1.25×104—3.35×104). The results indicated that flow field uniformization was enhanced in the shell side of shell-and-tube heat exchangers by two separated baffles parallel to segmental baffles and the performance of heat transfer was improved by controlling the dimension of vortices. The results could be used as reference in further research.